Configure Your FuzzyScan
2-25
Condensed DataWizard
i Preamble, Postamble, Data Length & Symbol ID Trans. i
PROGRAM M_DEFAULT
Family Code Selection P.C. Parameter Selection Option Code
Data Length Transmission
SS
SS
Disable
Enable 2-digits data length transmission
If data length exceeds 99, 3-digit data length will be transmitted.
0
1
Symbology ID Transmission
SS
SS
SS
SS
Disable symbol ID transmission
Enable prefix symbol ID transmission
Enable suffix symbol ID transmission
Enable both prefix and suffix symbol ID transmission
0
1
2
3
Data Pass Control
SS
SS
Disable (format match required)
Enable (format match not required)
If data verifier is false, the original scanned bar code data will be transmitted.
0
1
Data Sequence Control
SS
SS
Data output to host: Data Length first, then followed by Prefix Symbol ID
Data output to host: Prefix Symbol ID first, then followed by Data Length
0
1

DataWizard
is a very powerful, Artificial-Intelligence based data editing expert system provided specially for the FuzzyScan family bar code scanners. Through the
DataWizard
, you can process the scanned data prior the transmissions in many ways, such as:
Insert, Delete, Match, Verify, Replace, Reorganize
, and
Repeat
Transmission
. It also allows you to arrange the transmission of scanned data to any specific format without software modification.
Due to the resources used by this system,
Full-feature DataWizard
is only supported by
PowerTool
and
not
available on the FuzzyScan
Lite
series. Through the
PowerTool, all settings and configurations can be done on-screen, under Windows 95/98/NT environment.
To make the Preamble and Postable setting, please refer to the
Keyboard Interface Control
in page 2-20, or
Serial Interface Control
in page 2-22 for details.
A
Condensed Version DataWizard
is provided for all FuzzyScan scanner including Lite series and is utilized by scanning the programming bar codes.
When
Data Pass Control
is disabled, all input data must conform to an edited format or the scanner does not transmit the input data to the host.
To make the
Data Sequence Control setting
, you can refer to the
Keyboard Interface Message String
in page 2-19, or
Serial Interface Message String
in
page 2-22 for details.
Seitenansicht 32
1 2 ... 28 29 30 31 32 33 34 35 36 37 38 ... 50 51

Kommentare zu diesen Handbüchern

Keine Kommentare